Classic case of
The current position
:Home | Classic case of
In May 2009, We worked in an areas in Xinhua City,Jiangsu Province by CSAMT measurement. The task:” Investigate the geological structure and lithologic distribution where measuring lines covers by making use of electrical distribution within the measured sections, the depth is 3000m.”
Fig 1) the profile section for the inversion of resistivity
Fig 2) the profile section for the geologic interpretation
the profile section of work area in XingHua City for the first survey line used CSAMT
Fig 1) the profile section for the inversion of resistivity
Fig 2) the profile section for the geologic interpretation
the profile section of work area of XingHua City for the second survey line used CSAMT
The purpose is that suppose geological structure and the distribution of lithology in the area through a lot of measuring line, and then ensured the position of the drilling for geothermal resources exploration. According to the certain position of the drilling by CSAMT, we have drilled for testing and we have obtained hot water in 1600 meters of depth. The temperature of water is 42 °C.